Lucene search

K
TendaAc8v4 Firmware

15 matches found

CVE
CVE
added 2024/09/20 4:15 p.m.48 views

CVE-2024-46652

Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability in the fromAdvSetMacMtuWan function.

9.8CVSS7.4AI score0.00256EPSS
CVE
CVE
added 2023/08/21 1:15 a.m.37 views

CVE-2023-39786

Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sscanf function.

7.5CVSS7.7AI score0.00084EPSS
CVE
CVE
added 2024/07/09 6:15 p.m.37 views

CVE-2023-48194

Vulnerability in Tenda AC8v4 .V16.03.34.09 due to sscanf and the last digit of s8 being overwritten with \x0. After executing set_client_qos, control over the gp register can be obtained.

9.8CVSS6.9AI score0.00495EPSS
CVE
CVE
added 2023/08/24 6:15 p.m.34 views

CVE-2023-40898

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter timeZone at /goform/SetSysTimeCfg.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2023/08/21 1:15 a.m.33 views

CVE-2023-39784

Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the save_virtualser_data function.

7.5CVSS7.7AI score0.00084EPSS
CVE
CVE
added 2023/08/24 6:15 p.m.32 views

CVE-2023-40893

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2023/08/21 1:15 a.m.31 views

CVE-2023-39785

Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the set_qosMib_list function.

7.5CVSS7.7AI score0.00084EPSS
CVE
CVE
added 2023/08/24 6:15 p.m.30 views

CVE-2023-40896

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2023/08/24 6:15 p.m.30 views

CVE-2023-40897

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter mac at /goform/GetParentControlInfo.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2023/08/24 6:15 p.m.29 views

CVE-2023-40895

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2023/08/24 6:15 p.m.28 views

CVE-2023-40894

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetStaticRouteCfg.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2023/08/24 6:15 p.m.26 views

CVE-2023-40891

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter firewallEn at /goform/SetFirewallCfg.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2023/08/24 6:15 p.m.25 views

CVE-2023-40892

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter schedStartTime and schedEndTime at /goform/openSchedWifi.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2023/08/24 6:15 p.m.24 views

CVE-2023-40899

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.

9.8CVSS9.6AI score0.00121EPSS
CVE
CVE
added 2023/08/24 6:15 p.m.24 views

CVE-2023-40900

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.

9.8CVSS9.6AI score0.00121EPSS